Insulation selection

PrimaLoft — Shape the warmth brief from the inside

Start with the insulation reference, the garment layer it is meant to sit in, and the comparison you still need to make. Finished jackets stay outside this conversation.

Open an insulation brief
First step
Share a fill reference, a loft note, or the use the insulation has to serve.
Lofted synthetic insulation specimens beside a shell fabric swatch
Compare loft, hand and layer position with a physical specimen.

Development question map

Application goal

Name the warmth problem in the garment or gear layer: still air, damp use, pack volume, or a hand the designer already rejected.

Construction route

Separate fill weight, insulation construction and any bonding or scrim only when that construction is actually in the brief.

Evaluation gate

Agree which specimen, method and condition would make the next sample useful before anyone treats a keyword as a result.

Match the application

Material scope

Large unbranded insulation batt draped for a material review

Compare the insulation route

  1. Identify the insulation reference, not the finished garment.
  2. Confirm construction, loft context and any scrim or bonding that applies.
  3. Ask which finish or surface treatment is actually specified.
Browse insulation materials
Material brief

Questions before a comparison

Fields to agree; no product performance is implied
Field Target question Evidence question
Composition Which fiber statement belongs to this insulation reference? Which declaration or specimen record supports that statement?
GSM Is the figure a fill weight target, and in which unit? Was it measured on the insulation specimen you intend to discuss?
Usable width What cuttable width applies to the insulation form you need? Is width even part of this supply format, or is the form a package or cut piece?
Finish Is a surface treatment, scrim or bond actually specified? What sample state would make that finish note meaningful?

Write mass per unit area in g/m². A 200 g/m² note is a mass question until the area basis and the specimen are named. When the form is a broad piece, record usable width in centimetres apart from selvage. Check fiber composition as percent by mass, with the declared parts expected to sum to 100. Denier or dtex states linear density and is not a yarn count. Hydrostatic head, water vapor transmission, and air permeability answer different questions, and none of those results is pre-filled for PrimaLoft on this page.

Fabric selection questions

Why is a fill-weight number not a warmth answer?
A figure such as a target grams-per-square-metre note does not describe loft, construction, garment design or the test method. Ask which of those is actually being compared.
How should an insulation sample be described?
Give the reference name you have, the construction you can see, the layer it is meant to fill, and whether a shade or surface treatment is even relevant.
Can a wet insulation note be read as waterproof?
No. Water resistance and vapor transmission need their own methods, specimen conditions and report scope. An outdoor use story does not create either result.